EasyManuals Logo
Home>Manitowoc>Ice Maker>QD1392N

Manitowoc QD1392N Use And Care Manual

Manitowoc QD1392N
56 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #39 background imageLoading...
Page #39 background image
Section 3 Ice Machine Operation
Part Number 000001114 3-7
HARVEST SEQUENCE WATER PURGE
The harvest sequence water purge adjustment may be
used when the ice machine is hooked up to special
water systems, such as a de-ionized water treatment
system.
The harvest sequence water purge may be set to 15,
30, or 45 seconds.
During the harvest sequence water purge, the water
fill valve energizes and de-energizes by time. The
water purge must be at the factory setting of 45
seconds for the water fill valve to energize during the
last 15 seconds of the water purge. If it is set to less
than 45 seconds, the water fill valve will not energize
during the water purge.
Figure 3-10. Water Purge Adjustment
Important
The harvest sequence water purge is factory-set at
45 seconds. A shorter purge setting (with standard
water supplies such as city water) is not
recommended. This can increase water system
cleaning and sanitizing requirements.
15
30
45
SV1617
CONTROL
BOARD
WATER PURGE
ADJUSTMENT

Table of Contents

Other manuals for Manitowoc QD1392N

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Manitowoc QD1392N and is the answer not in the manual?

Manitowoc QD1392N Specifications

General IconGeneral
BrandManitowoc
ModelQD1392N
CategoryIce Maker
LanguageEnglish

Related product manuals