Installation Instructions Section 2
6
Part Number 000007651 05/10
Electrical Service
VOLTAGE
The maximum allowable voltage variation is ±10% of the
rated voltage on the ice machine model/serial number
plate at start-up (when the electrical load is highest).
GROUND FAULT INTERRUPTER CIRCUIT (GFIC)
Ground Fault Circuit Interrupter protection is a system
that shuts down the electric circuit (opens it) when it
senses an unexpected loss of power, presumably to
ground. Manitowoc does not recommend the use of a
GFCI/GFI circuit protection with our equipment. If code
requires the use of a GFCI/GFI then you must follow the
local code. The circuit must be dedicated, sized properly
and there must be a panel GFCI/GFI breaker. We do not
recommend GFCI/GFI outlets as they are known for
more intermittent nuisance trips than panel breakers.
FUSE/CIRCUIT BREAKER
A separate fuse/circuit breaker must be provided for
each ice machine. Circuit breakers must be H.A.C.R.
rated (does not apply in Canada).
QF0406A 115/60/1 ice machines are factory pre-wired
with a power cord and 5-15P plug confirmation.
QF0406A 230/50/1 ice machines are factory pre-wired
with a power cord, no plug is supplied.
TOTAL CIRCUIT AMPACITY
The total circuit ampacity is used to help select the wire
size of the electrical supply.
The wire size (or gauge) is also dependent upon
location, materials used, length of run, etc., so it must be
determined by a qualified electrician.
Electrical Requirements
Maximum Fuse Size
!
Warning
All wiring must conform to local, state and national
codes.
!
Warning
The ice machine must be grounded in accordance
with national and local electrical codes.
Ice Machine
Model
Voltage
Phase
Cycle
Maximum
Fuse/
Circuit
Breaker
Total
Circuit
Amps
QF0406A
115/1/60 15 6.9
230/1/05 15 4.2
For United Kingdom Only
As the colours of the wires in the mains lead of the appliance may not correspond with the coloured markings
identifying the terminals in your plug, proceed as follows:
The wire which is coloured green and yellow
must be connected to the terminal in the plug which is marked with
the letter E or by the earth ground symbol or coloured green or green and yellow.
The wire coloured blue
must be connected to the terminal which is marked with the letter N or coloured black.
The wire coloured brown
must be connected to the terminal which is marked with the letter L or coloured red.

Table of Contents

Other manuals for Manitowoc QF0400

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Manitowoc QF0400 and is the answer not in the manual?

Manitowoc QF0400 Specifications

General IconGeneral
BrandManitowoc
ModelQF0400
CategoryIce Maker
LanguageEnglish

Related product manuals