–171–
Fan Cycle Control
CVD0875/CVD1075/CVD1475/CVD1875/CVD2075
FUNCTION
Energizes and de-energizes the condenser fan motor.
The condenser fan motor typically will be on in the
Freeze cycle and off in the Harvest cycle.
The fan cycle control closes on an increase, and
opens on a decrease in discharge pressure.
CHECK PROCEDURE
1. Verify fan motor windings are not open or
grounded, and fan spins freely.
2. Connect manifold gauges to ice machine.
3. Hook voltmeter in parallel across the fan cycle
control, leaving wires attached.
4. Refer to chart below.
Specifications
Model Cut-In (Close) Cut-Out (Open)
CVD0875
CVD1075
CVD1475
CVD1875
250 psig ±5 200 psig ±5
CVD2075
250 psig ±5
275 psig ±5
200 psig ±5
225 psig ±5
FCC Setpoint:
Reading
Should Be:
Fan
Should Be:
Above Cut-In 0 Volts Running
Below Cut-Out Line Voltage Off