EasyManuals Logo
Home>Manitowoc>Ice Maker>QuietQube SY0874C

Manitowoc QuietQube SY0874C User Manual

Manitowoc QuietQube SY0874C
298 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #221 background imageLoading...
Page #221 background image
Part Number 80-1505-3 6/11 221
RECOVERY/EVACUATION PROCEDURES
1. Place the ICE/OFF/CLEAN toggle switch in the
OFF position and disconnect all power to the ice
machine and condensing unit.
2. Install manifold gauges, charging scale, and
recovery unit or two-stage vacuum pump.
3. Open the receiver service valve halfway.
4. Open high and low side on the manifold gauge
set.
5. Perform recovery or evacuation:
A. Recovery: Operate the recovery unit as
directed by the manufacturer’s instructions.
B. Pressure test the system.
C. Evacuation prior to recharging: Evacuate to
500 microns. Then allow the pump to run for
an additional hour.
6. Refer to Charging Procedures.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Manitowoc QuietQube SY0874C and is the answer not in the manual?

Manitowoc QuietQube SY0874C Specifications

General IconGeneral
BrandManitowoc
ModelQuietQube SY0874C
CategoryIce Maker
LanguageEnglish

Related product manuals