–198–
REFRIGERANT OIL
Manitowoc QuietQube ice machines use POE oil.
The recommended lubricant is Mobil EAL22A.
Refrigeration systems exposed to atmosphere for
more than 5 minutes must have the compressor oil
changed. The compressor must be removed and at
least 95% of the oil must be removed through the
suction port of the compressor. Measure the oil as it is
removed and replace with the same amount of new oil.