EasyManuals Logo
Home>Manitowoc>Ice Maker>SD0503W

Manitowoc SD0503W User Manual

Manitowoc SD0503W
300 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #140 background imageLoading...
Page #140 background image
140 Part Number 80-1479-3 7/10
CLEANING THE ICE THICKNESS OR WATER
LEVEL PROBE
Clean the probes using the following procedure.
1. Mix a solution of Manitowoc ice machine cleaner
and water (2 ounces of cleaner to 16 ounces of
water) in a container.
2. Soak probes in container of cleaner/water solution
while disassembling and cleaning water circuit
components (soak probes for 10 minutes or
longer).
3. Clean all probe surfaces including all plastic parts
(do not use abrasives). Verify all cavities are
clean. Thoroughly rinse probes (including cavity)
with clean water, then dry completely. Incomplete
rinsing and drying of the ice thickness probe
can cause premature harvest.
Reinstall probes, then sanitize all ice machine and bin/
dispenser interior surfaces.

Table of Contents

Other manuals for Manitowoc SD0503W

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Manitowoc SD0503W and is the answer not in the manual?

Manitowoc SD0503W Specifications

General IconGeneral
BrandManitowoc
ModelSD0503W
CategoryIce Maker
LanguageEnglish

Related product manuals