EasyManuals Logo
Home>Manitowoc>Ice Maker>SD0503W

Manitowoc SD0503W User Manual

Manitowoc SD0503W
300 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #73 background imageLoading...
Page #73 background image
Part Number 80-1479-3 7/10 73
2. Refrigeration System Start-Up
The compressor and liquid line solenoid valve
energize after the 45 second water purge and remain
on throughout the entire Freeze and Harvest
Sequences. The water fill valve is energized at the
same time as the compressor. It remains on until the
water level sensor closes for 3 continuous seconds, or
until a six-minute time period has expired. The harvest
valve and HPR solenoid valves remain on for 5
seconds during initial compressor start-up and then
shut off.
The remote condenser fan motor starts at the same
time the compressor starts and remains on throughout
the entire Freeze and Harvest Sequences.
Energized Control Board Lights-
Left Bin (green)

Table of Contents

Other manuals for Manitowoc SD0503W

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Manitowoc SD0503W and is the answer not in the manual?

Manitowoc SD0503W Specifications

General IconGeneral
BrandManitowoc
ModelSD0503W
CategoryIce Maker
LanguageEnglish

Related product manuals