Part Number 80-1479-3 7/10 255
S1600N
All Remote Air-cooled Condenser
Characteristics may vary depending on operating conditions.
CYCLE TIMES
Freeze Time + Harvest Time = Total Cycle Time
24 HOUR ICE PRODUCTION
OPERATING PRESSURES
Air Temp.
Entering
Condenser
°F/°C
Freeze Time
Harvest
Time
1
1 Times in minutes
Water Temperature °F/°C
50/10 70/21 90/32
-20/-29 to 70/21 10.4-11.5 11.2-12.3 12.4-13.6
1 - 2.5
80/27 10.5-11.5 11.7-12.8 12.5-13.7
90/32 10.8-11.9 11.7-12.8 13.0-14.3
100/38 11.7-12.8 12.9-14.1 13.8-15.2
110/43 10.4-11.5 11.2-12.3 12.4-13.6
Air Temp. Entering
Condenser
°F/°C
Water Temperature °F/°C
12
1 Based on average ice slab weight of 13 - 14.125 lb.
2 Ratings with JC1395 condenser
50/10 70/21 90/32
-20/-29 to 70/21 1570 1470 1350
80/27 1560 1420 1340
90/32 1520 1420 1290
100/38 1420 1300 1220
110/43 1570 1470 1350
Air Temp.
Entering
Condenser
°F/°C
Freeze Cycle Harvest Cycle
Discharge
Pressure
PSIG
Suction
Pressure
PSIG
Discharge
Pressure
PSIG
Suction
Pressure
PSIG
1
1 Suction pressure drops gradually throughout the freeze cycle
-20/-29 to
50/10
220-230 40-28 100-160 65-85
70/21 250-275 50-28 100-170 70-85
80/27 250-290 50-28 100-175 70-90
90/32 255-300 52-30 100-175 75-95
100/38 270-340 54-31 110-180 75-95
110/43 310-370 56-32 120-190 80-100