56 Part Number 80-1479-3 7/10
Drain Line Check Valve
The drain line check valve (not used on all models)
should be inspected and cleaned, whenever the ice
machine is cleaned.
1. Remove check valve and tube assembly.
A. Tip assembly to right until tubing disengages.
B. Lift up on assembly to remove.
2. Remove insulation from check valve assembly.
3. Remove vinyl tubing from top of check valve.
4. Soak in cleaner solution 10 minutes, and then
flush with water to remove debris.
CHECK VALVE
ASSEMBLY
CHECK VALVE

Table of Contents