252 Part Number 80-1479-3 7/10
SY1494N
Half Dice Cube, Remote Condenser Air-Cooled With a
Manufacture Date of 0905 (May 2009) or Later
Characteristics may vary depending on operating conditions.
CYCLE TIMES
Freeze Time + Harvest Time = Total Cycle Time
24 HOUR ICE PRODUCTION
OPERATING PRESSURES
Air Temp.
Entering
Condenser
°F/°C
Freeze Time
Harvest
Time
1
1 Times in minutes
Water Temperature °F/°C
50/10 70/21 90/32
70/21 8.8-10.1 9.7-11.0 10.6-12.1
0.75 - 2.5
80/27 9.0-10.3 9.9-11.3 10.9-12.4
90/32 9.3-10.6 10.5-12.0 11.2-12.8
100/38 9.9-11.2 11.2-12.8 12.0-13.7
110/43 10.6-12.1 12.0-13.7 13.1-14.9
Air Temp. Entering
Condenser
°F/°C
Water Temperature °F/°C
12
1 Based on average ice slab weight of 10.25 - 11.5 lb
2 Ratings with JC1395 condenser
50/10 70/21 90/32
70/21 1430 1320 1220
80/37 1400 1290 1190
90/32 1370 1230 1160
100/38 1300 1160 1090
110/43 1220 1090 1010
Air Temp.
Entering
Condenser
°F/°C
Freeze Cycle Harvest Cycle
Discharge
Pressure
PSIG
Suction
Pressure
PSIG
Discharge
Pressure
PSIG
Suction
Pressure
PSIG
1
1 Suction pressure drops gradually throughout the freeze cycle
-20/-29 to
50/10
210-240 38-24 100-160 70-85
70/21 240-265 40-26 110-170 70-90
80/27 250-275 45-28 110-180 70-95
90/32 250-290 48-29 110-180 70-95
100/38 275-335 51-31 110-185 75-100
110/43 310-375 55-32 120-190 80-110