Part Number 80-1479-3 7/10 251
SD1492N
Dice Cube, Remote Condenser Air-Cooled With a
Manufacture Date of 0905 (May 2009) or Later
Characteristics may vary depending on operating conditions.
CYCLE TIMES
Freeze Time + Harvest Time = Total Cycle Time
24 HOUR ICE PRODUCTION
OPERATING PRESSURES
Air Temp.
Entering
Condenser
°F/°C
Freeze Time
Harvest
Time
1
1 Times in minutes
Water Temperature °F/°C
50/10 70/21 90/32
70/21 9.2-10.5 10.1-11.5 10.8-12.3
0.75 - 2.5
80/27 9.4-10.7 10.3-11.7 11.0-12.5
90/32 9.6-11.0 10.7-12.2 11.4-13.0
100/38 10.4-11.9 11.7-13.3 12.6-14.3
110/43 11.2-12.8 12.7-14.4 13.7-15.6
Air Temp. Entering
Condenser
°F/°C
Water Temperature °F/°C
12
1 Based on average ice slab weight of 10.25 - 11.5 lb
2 Ratings with JC1395 condenser
50/10 70/21 90/32
70/21 1380 1270 1200
80/37 1360 1250 1180
90/32 1330 1210 1140
100/38 1240 1120 1050
110/43 1160 1040 970
Air Temp.
Entering
Condenser
°F/°C
Freeze Cycle Harvest Cycle
Discharge
Pressure
PSIG
Suction
Pressure
PSIG
Discharge
Pressure
PSIG
Suction
Pressure
PSIG
1
1 Suction pressure drops gradually throughout the freeze cycle
-20/-29 to
50/10
210-240 38-24 100-160 70-85
70/21 240-265 40-26 110-170 70-90
80/27 250-275 45-28 110-180 70-95
90/32 250-290 48-29 110-180 70-95
100/38 275-335 51-31 110-185 75-100
110/43 310-375 55-32 120-190 80-110