50 Part Number 80-1479-3 7/10
bin (or dispenser). Use a cloth or sponge to liberally
apply the solution. When sanitizing, pay particular
attention to the following areas:
Side walls
Base (area above water trough)
Evaporator plastic parts - including top, bottom and
sides
Bin or dispenser
Do not rinse the sanitized areas.
Step 13 Replace all removed components.
Step 14 Reapply power to the ice machine and place
the toggle switch in the CLEAN position.
Step 15 Wait about two minutes or until water starts
to flow over the evaporator. Add the proper amount of
Manitowoc Ice Machine Sanitizer to the water trough
by pouring between the water curtain/splash shields
and evaporator.
Step 16 The ice machine will stop after the sanitize
cycle (approximately *35 minutes). Place the toggle
switch in the OFF position and disconnect power to
the ice machine.
*S3300 Only - 80 minutes.
Step 17 Refer to step 6 and disassemble
components. After dissembling proceed to step 18.
Step 18 Mix a solution of sanitizer and warm water.
Model Amount of Sanitizer
S300/S320/S420 3 ounces (90 ml)
S450/S500/S600/S850/
S1000/S1200
3 ounces (90 ml)
S1400/S1600/S1800 6 ounces (180 ml)
S3300 25 ounces (740 ml)
!
Warning
Disconnect the ele ctric po wer to th e ice
machine at the electric service switch box.

Table of Contents

Other manuals for Manitowoc SY0855W

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Manitowoc SY0855W and is the answer not in the manual?

Manitowoc SY0855W Specifications

General IconGeneral
BrandManitowoc
ModelSY0855W
CategoryIce Maker
LanguageEnglish

Related product manuals