Part Number 80-1479-3 7/10 25
CALCULATING REMOTE CONDENSER
INSTALLATION DISTANCES
NOTE: Manitowoc warrants only complete new and
unused remote packages. Warranty on the
refrigeration system will be void if a new ice machine
head section is connected to existing (used) tubing or
condensers.
Line Set Length
The maximum length is 100' (30.5 m).
The ice machine compressor must have the proper oil
return. The receiver is designed to hold a charge
sufficient to operate the ice machine in ambient
temperatures between -20°F (-28.9°C) and 120°F
(49°C), with line set lengths of up to 100' (30.5 m).
Line Set Rise/Drop
The maximum rise is 35' (10.7 m).
The maximum drop is 15' (4.5 m).
!
Caution
If a li ne se t h as a rise fo llowed by a drop , a nother
rise cann ot be mad e. Likew ise, if a li ne se t h as a
drop fo llowed by a rise, another drop cannot be
made.