Sizes in mm
1.2.3
Scribe the drill holes and fit fastening
fixtures with suitable fastening plates according to
the background. Align the fastening fixtures
horizontally!
With uneven facades, check the spaces with a
length of cord and if necessary compensate.
Fixtures must be aligned to each other!
1.3 Top Fixture
1.3.1
Determine the fitting height.
Determine the position of the fixtures according to
the stickers already provided (red points) on the
back of the cassette (see also 1.2.1 Face Fixture).
1.3.2
Attention! The distance of the bracket to a
possibly existent wall must be at least 65mm!
1.3.3
Concrete (B 25) i
background. Fastening materials are not supplied,
different fastening systems are offered by
fastenings manufacturers (e.g. Fischer, Hilti, Upat
etc.).
The corresponding extend forces from our sales
literature are to be taken into consideration. If the
requirements for fastening are observed, according
to DIN EN 13561, for the user Wind Resistance
Class 2 can be confirmed for the installation.