Mercury Security © 2018 LP2500 DOC 10107-0063 REV 1.02 Page 4
8. Status LEDs:
Power-up: All LED's OFF.
Initialization: After power is applied or reset switch pushed, LED 1 is ON for about 15 seconds, then LED’s 2
through 6 are flashed once at the beginning of initialization. LEDs 3 and 4 is turned ON for approximately 1
second after the hardware initialization has completed, then the application code is initialized. The amount of
time the application takes to initialize depends on the size of the database, about 1 second without a card
database. Each 10,000 cards will add about 2 seconds to the application initialization. When LED's 1
through 4 flash at the same time, data is being read from or written to flash memory, do not cycle power when
in this state. If the sequence stops or repeats, perform the bulk erase procedure, see section 4.
Running:
9. IT Security
When installing the LP2500, it is important to ensure that it is done in a secure manner.
Upon installation, the user accounts to the web configuration page should be created with secure
passwords, and that all DIP switches are in the off position for the normal operating mode. The LP2500 is
shipped from the factory with a default login account, which is enabled when DIP 1 is moved from OFF to
ON. The default login user name and password will be available for five minutes once enabled. Therefore,
it is important that at least one user account is defined, and the DIP switches are set to OFF before the
LP2500 is commissioned. It is also highly recommended not to configure the LP2500 with an IP address
that is accessible from the public Internet.
To further enhance network security, options are available to disable SNMP, Zeroconf discovery, as well
as the web configuration module itself. Additionally, data encryption can also be enabled over the host
communication port.
10. Specifications:
** The interface is for use in low voltage, Class 2 Circuits only.
The installation of this device must comply with all local fire and electronic codes.
Primary Power: 12 to 24 Vdc ± 10%, 250 mA maximum
(USB port current not included)
Micro USB Port: 5 Vdc, 500 mA maximum (add 270 mA to primary power current)
Memory and
Clock Backup: 3 Volt Lithium, type BR2330 or CR2330
microSD Card: Format: microSD or microSDHC; 2GB to 8GB.