EasyManuals Logo
Home>Meterman>Multimeter>33XR

Meterman 33XR User Manual

Meterman 33XR
20 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #6 background imageLoading...
Page #6 background image
4
Measuring DC Current See Figure -3-
1. Set the Range Switch to an appropriate
A
range.
Select the highest range and work down if the current level is unknown.
2. Connect the Test Leads: Red to mA or 10A, Black to COM
3. Turn off power to the circuit being measured.
4. Open the test circuit (
X
) to establish measurements points.
5. Connect the Test Probes in series with the load.
6. Turn on power to the circuit being measured.
7. Read the display, and, if necessary, fix any overload (
o
) conditions.
Measuring AC Current See Figure -4-
1. Set the Range Switch to an appropriate
a
range.
Select the highest range and work down if the current level is unknown.
2. Connect the Test Leads: Red to mA or 10A, Black to COM
3. Turn off power to the circuit being measured.
4. Open the test circuit (
X
) to establish measurements points.
5. Connect the Test Probes in series with the load.
6. Turn on power to the circuit being measured.
7. Read the display, and, if necessary, fix any overload (
o
) conditions.
Measuring Resistance See Figure -5-
1. Set the Range Switch to an appropriate range.
Select the highest range and work down if the resistance level is unknown.
2. Connect the Test Leads: Red to
E
, Black to COM
3. Turn off power to the circuit being measured. Never measure resistance across
a voltage source or on a powered circuit.
4. Discharge any capacitors that may influence the reading.
5. Connect the Test Probes across the resistance.
6. Read the display. If
o
appears on the highest range, the resistance is too large
to be measured.
Measuring Continuity See Figure -6-
1. Set the Range Switch to
R
.
2. Connect the Test Leads: Red to
E
, Black to COM
3. Turn off power to the circuit being measured.
4. Discharge any capacitors that may influence the reading.
5. Connect the Test Probes across the resistance.
6. Listen for the tone that indicates continuity (< 35 ).
Checking Diodes See Figure -7-
1. Set the Range Switch to
G
.
2. Connect the Test Leads: Red to
E
, Black to COM
3. Turn off power to the circuit being measured.
4. Free at least one end of the diode from the circuit.
5. Connect the Test Probes across the diode.
6. Read the display. A good diode has a forward voltage drop of about 0.6 V. An
open or reverse biased diode will read
o
.

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Meterman 33XR and is the answer not in the manual?

Meterman 33XR Specifications

General IconGeneral
BrandMeterman
Model33XR
CategoryMultimeter
LanguageEnglish