code
Reason Description Solution
E10
The water level
doesn’t changed in 3
minutes during filling
the water.
Open the water tap, to check if the
inlet hose is squashed or kinked,
check the filter in the inlet valve is
blocked or not; check if the water
pressure is too low.
The water level is
higher than the
overflow water level.
Check the water inlet valve, Valve fail
Fault connection
of the drain pump
doesn’t changed in 3
minutes during drain
the water.
Check the drain pump.
Check the filter of the drain pump
to prevent jam.
Check the drain hose to prevent
jam.
Overtime 3min
of the drainage
The door has not
been closed over
3 times
Fail to lock the door
lock for 6 times when
the PCB ties to lock the
door lock after you
press the Start keys.
Check the door hook and the door
lock to get correct location.
Don’t unlock the
door lock
Fail to unlock the door
lock 6 times
The frequency of the
water level sensor is
out of the spec.
Check the water level sensor
The temperature
sensor(NET) get broken
Check the PCB and the motor
The motor don’t drive
for
-
out
Check the PCB and the motor
Check the motor communicate
wire
The speed don’t
transmit signal
The PCB can’t get
speed transmit signal
when the motor drive
Check the speed transmit line of
the motor to prevent fall
Check the PCB and the motor
Check the motor communicate
wire
4 MALFUNCTION CODES AND EXPLANATIONS
Schedule of failure alarm