32802002001 Specifications subject to change without notice. 3
ACCESSORIES
The system is shipped with the following accessories (see
Table 1). Keep the owner's manual in a safe place and do not
discard any accessories until the installation has been
completed.
Table 1 — Accessories
Fig. 1 — Indoor Unit Representation
Wireless Remote Control (Included)
The wireless remote is only to be used by the installation
contractor to adjust airflow settings in accordance with static
pressure curves in installation manual.
Built-In 24V Interface Standard
Allows the control of the air handler with a third party
thermostat (field supplied).
DISPLAY PANEL
The Display Panel is shipped inside the Control Box and it is
used as an infrared receiver for the wireless remote controller
shipped with the unit for the purpose of setting airflow by the
installation contractor.
Fig. 2 — IR (Infrared) Receiver Display Panel
AUTO START
If the power fails while the unit is operating, the unit stores the
operating condition, and the unit automatically starts operating
under those conditions once the power is restored.
NAME SHAPE QUANTITY
Owner’s and Installation
Manual
(An updated version may
be available online)
1
Wireless Remote
Controller
1
Battery 1
Infrared Display Panel
(located in the Air Handler
Unit)
1
ON/OFF
TEMP
FP
TIMER
ON
TIMER
OFF
MODE
FAN/SLC
SLEEP
TURBO
SWING
DIRECT
CLEAN
LED
FOLLOW
connecting
pipe
Blower
Coil
Coil Compartment
(Access Panel Removed)
Infrared receiver
Timer indicator
Alarm indicator
PRE-DEF
(pre-heating/defrost)
indicator
Operation indicator