2 TEST MODE
Before starting test mode, the water level sensor should be installed.
Otherwise, the unit will alarm and stop running test mode.
Test 1:Anytime you enter the test mode, all lights and digital will be ON
and then flash with 6 beeps. If any light is not ON, replace the PCB. If the
digital in not 88 displayed, replace the PCB. If you can’t hear the beep,
replace the PCB.
Test 2:Washing test, to check the motor and rotate directions.
In 9 seconds after entered test mode, press button Soil Level to enter
Washing test.
The Normal cycle light, Wash procedure light will be ON in Washing test.
The digital time will display 3 indicating that the remaining time is 3
minutes.
The motor and impeller will rotate in two-directions in turn.
The test mode will end with 6 beeps and Done light flashing after 3
minutes’ operation. All lights will be OFF when the lid is opened.
Test 3:Spinning test, to check clutch and pump.
In 9 seconds after entered test mode, press button Temp to enter Spinning
test.
The Normal cycle light, Spin procedure light will be ON in Spinning test.
The digital time will display 3 indicating that the remaining time is 3
minutes.
The pump will start in 8 seconds. Another 2 seconds later, the unit will start
Spinning test.
The test mode will end with 6 beeps and Done light flashing after 3
minutes’ operation. All lights will be OFF when the lid is opened.
Test 4: Inlet valve test, Software version check
In 9 seconds after entered test mode, press button Fabric Softener to enter
Inlet valve test.
7