1. PREFACE
1.1 SAFETY PRECAUTIONS..................................................................................1
1.2 INSULATION RESISTANCE TEST......................................................................1
1.3 SPECIFICATIONS............................................................................................2
1.4 FEATURES......................................................................................................4
1.5 DISPLAY PANEL AND REMOTE CONTROL........................................................4
2. INSTALLATION
2.1 NAMES OF PARTS...........................................................................................5
2.2 WINDOW INSTALLATION.................................................................................6
3. TROUBLESHOOTING GUIDE
3.1 PIPING SYSTEM..............................................................................................7
3.2 ELECTRIC FUNCTION......................................................................................7
3.3 TROUBLESHOOTING GUIDE............................................................................8
4. SCHEMATIC DIAGRAM
4.1 CIRCUIT DIAGRAM.........................................................................................13
5. EXPLODED VIEW AND REPLACEMENT
PARTS LIST.................................................. ....................................................14
1.PREFACE
This SERVICE MANUAL provides various service information, including the mechanical and electrical
parts etc. This room air conditioner was manufactured and assembled under a strict quality control system.
The refrigerant is charged at the factory. Be sure to read the safety precautions prior to servicing the unit.
1.1 SAFETY PRECAUTIONS
1. When servicing the unit, set the POWER SWITCH to OFF and unplug the power cord.
2. Observe the original lead dress.
If a short circuit is found, replace all parts which have been overheated or damaged by the short circuit.
3. After servicing the unit, make an insulation resistance test to protect the customer from being exposed to
shock hazards.
1.2 INSULATION RESISTANCE TEST
1. Unplug the power cord and connect a jumper between 2 pins (black and white).
2. The grounding conductor (yellow/green) is to be open.
3. Measure the resistance value with an ohm metre between the jumped lead and each exposed metallic part
on the equipment at all the positions.
4. The value should be over 1M .
1