15
7.5.2.1 If TATS+1, the outdoor fan operates. After 15 seconds, the compressor operates.
7.5.2.2 The compressor is on, if TATS, this compressor will stop. If the outdoor fan operates for 3
minutes at least, it will stop after delaying for 5 seconds.
7.5.3. When the unit is off, the compressor stops at first, and the indoor/outdoor fan will stop after
delaying for 5seconds. (If it operates in heating mode, the outdoor fan will be off delaying for 30
seconds).
7.5.4. The TIMER function is valid in cooling mode.
7.6 Drying mode
7.6.1. The unit operates in drying mode. If TA>13, outdoor fan turns on, and then the compressor
operates after 15 seconds later.
7.6.1.1 When TA<13, the compressor stops working. And the outdoor fan will stop delaying for 5
seconds until it operates for 3minutest.
7.6.1.2 When TA14, the outdoor fan operates, and the compressor will restart to operate after
15seconds.
7.6.2. The speed cant be controlled in drying mode, and the indoor fan motor operates at low speed.
(T A -T s )
+1
0
C o m pre ssor o n
O p e ration c o n d ito n
C o m pre ssor o ff
T A
15
13
C o m p resso r on
O p e ratio n c o n d iton
C o m p ressor o ff
14