Service manual
- 7 -
4. Specification
MSG-24CR MSG-24HR
Capacity Btu/h
24000 24000
Input W
2750 2750
Rated current A
12.5 12.5
EER Btu/w.h
8.7, 2.6 8.7, 2.6
Capacity Btu/h
-----
27000
Input W
----- 2750
Rated current A
-----
12.5
COP W/W
----- 2.9
A
16 16
A
50 50
Model
QP407PT24C QP407PT24C
Type
Rotary Rotary
Brand
LG LG
Capacity Btu/h
23400 23400
Input W
2317 2317
Rated current(RLA) A
10.1 10.1
Locked rotor Amp(LRA) A
54 54
Thermal protector
Internal Internal
Capacitor uF
45 45
Refrigerant oil ml
650 650
Model
YDK36-4G YDK36-4G
Brand
Welling Welling
Input W
65/63/60 65/63/60
Capacitor uF
2
F/450V 2
F/450V
Speed(hi/mi/lo) r/min
1050/950/850 1050/950/850
m3/h
1050/950/850 1050/950/850
dB(A)
43/40/37 43/40/37
Model
YDK53-6K YDK53-6K
Brand
Welling Welling
Input W
130 130
Capacitor uF
3.5 3.5
Speed r/min
800 800
3
2500 2500
dB(A)
56
56
g
R22/1850 R22/1900
MPa
2.6 2.6
Liquid side/ Gas side mm
9.53/
16.0
9.53/
16.0
Max. refrigerant pipe length m
20 20
Max. difference in level m
10 10
℃
17-30 17-30
℃
18-45 -7 - 45
2
40~56 40~56
Model
Power supply
Cooling
Heating
Max. current
Starting current
Compressor
Indoor
fan motor
Indoor air flow (Hi/Mi/Lo)
Indoor noise level (Hi/Mi/Lo)
Outdoor
fan motor
Outdoor air flow
Operation temp
Ambient temp
Application area
Outdoor noise level
Refrigerant type R410A
Design pressure
Refrigerant
piping
Note:
The noise date is base on hemi-anechoic chamber, during actual operation; these values are normally somewhat
different as a result of ambient condition.
The above design and specifications are subject to change without prior notice for product improvement.