9 Basic test procedure
9.1 Defective compressor
Compressors are single phase, 115 or 230/208 volt, depending on the model unit. All compressor
motors are permanent split capacitor type using only a running capacitor across the start and run
terminal.
All compressors are internally spring mounted and externally mounted on rubber isolators.
9.1.1 Compressor wiring test
Remove compressor terminal box cover and disconnect wires from terminals. Using an
ohmmeter, check continuity across the following:
Terminal "C" and "S" - no continuity
- Open winding - replace compressor.
Terminal "C" and "R" - no continuity
- Open winding - replace compressor.
Terminal "R" and "S" - no continuity
- Open winding - replace compressor.
9.1.2 Ground test
Use an ohmmeter set on its highest scale. Touch one lead to the compressor body (clean point of
Double louver
flat appearanceSimple and generous
Straight condenser low costHigh-efficiency
duct insideAfter the lower right panel
High heat exchanger designed
Turbo cooling function
Flexible air exhaust
Advanced shower system
Follow me function
24 hour on/off
Cooling
Dry
Fan only
No water tank design

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Midea N series and is the answer not in the manual?

Midea N series Specifications

General IconGeneral
BrandMidea
ModelN series
CategoryAir Conditioner
LanguageEnglish

Related product manuals