Solution
Air conditioner
does not start
Wall plug disconnected. Push plug firmly into wall outlet.
House fuse blew or circuit breaker tripped. Replace fuse with time delay type or
reset circuit breaker.
Selector Control in OFF position. Turn selector to the desired FAN or COOL setting.
TROUBLESHOOTING TIPS
Problem
Air from unit does
not feel cold
enough
Thermostat set too warm. Set thermostat to colder temperature.
Turn selector to a higher COOL position.
Temperature sensing tube is touching the cold coil located behind the air filter.
Unit turned off by moving thermostat to a higher number and then immediately
turning back to a colder number. Wait approximately 3 minutes before changing. Listen
Unit turned off and then on too quickly. Turn unit off and wait 3 minutes before
restarting.
Room temperature below 18 C(64 F). Cooling may not occur until room temperature
rises above 18 C(64 F).
O
O
O
O
Thermostat set too cold for night-time cooling. To defrost the coil, set selector to a
FAN position. Then, set thermostat to a warmer position.
Air filter may be dirty. Clean filter. Refer to Care and Cleaning section. To defrost,
set selector to FAN.
Air conditioner
cooling, but room
is too warm- ice
forming on cooling
coil behind
decorative front.
Outdoor temperature below 18 C(64 F). To defrost the coil, set selector to FAN
position. Then, set thermostat to warmer position.
O
O
Before calling for service, review this list. It may save you time and money.
This list includes common occurences that are not the result of defective workman-
ship or material in this appliance.
for compressor to start.
Thermostat set too low. Adjust thermostat to higher number for cooling.
Straighten tube away from coil.
Clean your air conditioner occasionally to keep it looking new. Be sure to unplug
the unit before cleaning to prevent shock or re hazards.
CAUTION
Air Filter Cleaning
The air filter should be checked at least once a
month to see if cleaning is necessary. Trapped
particles in the filter can build up and cause an
accumulation of frost on the cooling coils.
CARE AND CLEANING
Cabinet Cleaning
Hold the slot under the front panel, then uplift it onwards, and remove the front panel.
Pinch the handle under the air filter and make the air filter
arched, remove it from the underside to upside.
Wash the filter using liquid dishwashing detergent and warm
water. rinse filter thoroughly.
Gently shake excess water from the filter. Be sure the filter
is thoroughly dry before putting it back.
Or, instead of washing you may vacuum the filter to clean.
Note: Never use hot water over 40°C (104°F) to clean the
air filter. Never attempt to operate the unit without the air filter.
Be sure to unplug the air conditioner to prevent shock or fire hazard. The cabinet and
front panel may be dusted with an oil-free cloth or washed with a cloth dampened in a
solution of warm water and mild liquid dishwashing detergent. Rinse thoroughly and
wipe to dry.
Never use harsh cleaners, wax or polish on the cabinet and front panel.
Be sure to wring excess water from the cloth before wiping around the controls.
Excess water in or around the controls may cause damage to the air conditioner.
Plug in air conditioner.
Note: Never use water over 50°C, alcohol, gasoline, acid, solvent or brush to clean the
17