Installation
*INSTALLATION*
45
When installing a condensate trap,
ensure that it is positioned vertically
and as closely as possible to the cooker
hood above the exhaust connection.
The arrow on the casing indicates the
direction of airflow.
The condensate trap will be integrated
in cooker hoods which are designed to
be connected to an external motor
(EXT/EXTA models).
Miele shall not accept warranty claims
for any functional defects or damage
caused by inadequate exhaust
ducting.
Silencer
To reduce noise levels even further, a
silencer (optional accessory) can be
installed in the exhaust ducting.
In extraction mode, the silencer not only
reduces noise from the fan outside the
house, but also sounds originating
outside reaching the kitchen through
the exhaust ducting (e.g. traffic noise).
For this reason, the silencer must be
positioned as close as possible to the
ducting exit.
In recirculation mode, the silencer
needs to be positioned between the
exhaust vent and the exhaust grille.
Check that there is sufficient space.
For operation with an external motor,
noise from the motor outside the house
and inside the kitchen can be