Installation PG 8059
08.12.2015
5
Technical data sheet
Commercial dishwasher
PG 8059
Legend:
Circled, bold-type abbreviations:
Connection required
GB
Abbreviations surrounded by broken circle:
Connection optional or required, depending on model
Electrical
connection
1. Voltage (standard version)
V/Hz 3N AC 400/50
Power rating kW 8.9
Fuse rating A 3 × 16
Connection cable, min. gauge mm² 5 × 2.5
Connection cable length (H05(07)RN-F) without
plug
m Approx. 1.7
Voltage
Convertible
V/Hz AC 230/50
Power rating kW 3.4
Fuse rating A 16
Connection cable, min. gauge mm² 3 × 1.5
Length of connection cable (H05(07)RN-F) with
plug
m Approx. 2.1
Variations in the following countries:
2. Voltage (standard version)
V/Hz 3 AC 230/50
Power rating kW 7.1
Fuse rating A 3 x 20
Connection cable, min. gauge mm² 4 x 2.5
Connection cable length (H05(07)RN-F) without
plug
m Approx. 1.7
Voltage
Convertible
V/Hz AC 230/50
Power rating kW 3.4
Fuse rating A 16
Connection cable, min. gauge mm² 3 × 1.5
Length of connection cable (H05(07)RN-F) with
plug
m Approx. 2.1
3. Voltage (standard version)
Convertible
V/Hz 3N AC 400/50
Power rating kW 8.9
Fuse rating A 3 x 15-16
Connection cable, min. gauge mm² 5 x 2.5
Connection cable length (H05(07)RN-F) without
plug
m Approx. 2.1
Voltage (standard version)
Convertible
V/Hz AC 230/50
Power rating kW 5.9
Fuse rating A 30-32
Connection cable, min. gauge mm² 3 x 4
Length of connection cable (H05(07)RN-F) with
plug
m Approx. 2.1
Voltage
Convertible
V/Hz AC 230/50
Power rating kW 3.4
Fuse rating A 13-16
Connection cable, min. gauge mm² 3 x 1.5
Length of connection cable (H05(07)RN-F) with
plug
m Approx. 2.1