APPENDICES
APP
2
(2) MR-HBUS
M
(a) Explanation of type
Type: MR-HBUS M
Symbol Cable Length [m]
05 0.5
1
5
1
5
(b) Connection diagram
When fabricating a cable, use the recommended wire given on Appendix
1.1 (1), and make the cable as shown in the following connection diagram.
The overall distance of the SSCNET cables on the same bus is 30m.
1
LG
11
LG
2
RD
12
RD*
4
TD
14
TD*
5LG
15
LG
6EMG
16
EMG*
9BT
20SD
1
11
2
12
4
14
5
15
6
16
9
20
PCR-S20FS(connector)
PCR-LS20LA1(case)
PCR-S20FS(connector)
PCR-LS20LA1(case)
MR-HBUS M