EasyManuals Logo
Home>Mitsubishi Heavy Industries>Air Conditioner>DXK18Z6-W

Mitsubishi Heavy Industries DXK18Z6-W User Manual

Mitsubishi Heavy Industries DXK18Z6-W
26 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #24 background imageLoading...
Page #24 background image
EN-23
Self diagnosis function
We are constantly trying to do better service to our customers by installing such judges that show abnormality of each function as follows
RUN light
TIMER light ON
1-time flash
2-time flash
5-time flash
7-time flash
6-time flash
Description of trouble Cause
Indoor heat exchanger sensor 1
error
Room temperature sensor error
Circuit error
Indoor fan motor error
Refrigerant is insufficient
Closed service valve
Broken heat exchanger sensor 1 wire, poor connector
connection
Broken room temperature sensor wire, poor connector
connection
Circuit failure or poor connector connection
Defective fan motor, poor connector connection
Refrigerant is insufficient, leaking
Closed service valve
TIMER light
4-time flash
2-time flash
1-time flash
3-time flash
2-time flash
1-time flash
4-time flash
5-time flash
6-time flash
7-time flash
Keep flashing
2-time flash
RUN light keeps flashing
RUN light ON
RUN light 2-time flash
Outdoor temperature sensor error
Outdoor heat exchanger sensor
error
Discharge pipe sensor error
Broken outdoor sensor wire, poor connector connection
Broken heat exchanger sensor wire, poor connector
connection
Broken discharge pipe sensor wire, poor connector connection
Current cut
Trouble of outdoor unit
Over current
Power transistor error
Over heat of compressor
Error of signal transmission
Outdoor fan motor error
Cooling high pressure protection
Compressor locking, open phase on compressor output,
short circuit on power transistor, closed service valve
Broken compressor wire
• Compressor blockage
Overload operation, overcharge of refrigerant
Broken power transistor
Gas shortage, defective discharge pipe sensor,
closed service valve
Defective power source, broken signal wire, defective
indoor/outdoor unit boards
Defective fan motor, poor connector connection
Overcharge of refrigerant, short circuit of outdoor unit
Rotor lock
• Defective compressor
Open phase on compressor
Defective outdoor unit boards
RLC012A103_EN.indd 23RLC012A103_EN.indd 23 9/25/2018 11:57:43 AM9/25/2018 11:57:43 AM

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Mitsubishi Heavy Industries DXK18Z6-W and is the answer not in the manual?

Mitsubishi Heavy Industries DXK18Z6-W Specifications

General IconGeneral
BrandMitsubishi Heavy Industries
ModelDXK18Z6-W
CategoryAir Conditioner
LanguageEnglish

Related product manuals