EasyManuals Logo

Mitsubishi Heavy Industries FDTC25VH User Manual

Mitsubishi Heavy Industries FDTC25VH
167 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #152 background imageLoading...
Page #152 background image
-
150
-
'19 • SCM-SM-276
Error code
Remote control:
LED Green Red
Indoor
Outdoor
Content
Error code
Remote controller: E51
LED Green Red
Indoor
Content
Power transistor error
(Models SRC50, 60)
Keeps flashing
Stays Off
1. Applicable model
5. Troubleshooting
All models
Diagnosis Countermeasure
2. Error detection method
3.
Condition of error displayed
4. Presumable cause
Note:
If the power transistor primary
current exceeds the setting value
for 3 seconds, the compressor
stops.
Power transistor primary current
• Outdoor unit main PCB
anomaly
• Dust on outdoor unit main PCB
• Blown F2 fuse
Check soldered
surfaces on the outdoor unit main PCB
for
foreign matter like dust,
fouling,etc.
Is F8 fuse
(250V, 20A)blown?
Remove foreign matter
like dust, fouling, etc.
Replace fuse.
Defective outdoor unit
main PCBReplace.
YES
NO
NO
YES
E51
Power transistor anomaly
Keeps ashing
Stays OFF
1
-
time ash

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Mitsubishi Heavy Industries FDTC25VH and is the answer not in the manual?

Mitsubishi Heavy Industries FDTC25VH Specifications

General IconGeneral
BrandMitsubishi Heavy Industries
ModelFDTC25VH
CategoryAir Conditioner
LanguageEnglish

Related product manuals