3. ELECTRICAL WIRING
Compressor
L3
TB1
L1
L2
CNFAN2RD CNEEV1RD
EEVH3
CNEEV2BL
FMo1 FMo2
CNFAN1WH
CH1
CNWRD
63H1-1
CNR1WH CNM1GY CNN1RD CNQ1WH
N
CT1
L1-1
+
R1-3
C1-1
Noisefilter
PWB3-1
L1i
E
L2i L3i Ni
L1o L2o L3o No
-
+
DM1
AC1
AC2
AC3
+
R1-4
C1-2
V
U
W
CM1
CNRWH
IPM1
PN
VU W
CNAWH
L3
CNI3BK
52X1-2
52X1-1
CNN2GN
20S1
CNN9BK CNN6PK
PSH
PSL
RD
WH
BK
WH
BK
RD
TB2
A1
B1
A2
B2
CNSL1,2
WH
WH
BK
BL
WH
BK
NETWORKCONNECTOR
Inverter
PWB2-1
LED1
(INV)
EEVH2
CNEEV3WH
BK
FMC1
SV1SV6 SV11
Powersource
3Phase
380-415V50Hz
/380V60Hz
Signalline
CNTHWH RD
CNB2
BK
CNB3
RD
CNB4
WH
CNF1
GN
CNF2
YE
CNP1
BL
CNU1
CNL1BL
CNL2WH
Reserve
output
Trouble
output
Cooling/Heating
forcedinput
Silentmode
input
External
input
Operation
output
Demand
input
CNZ1RD
CNHBL
CNYWH
CNG1BL
CNG2WH
CNS1GN
CNS2RD
CNN8PK
WH WH
PWB1
CONTROL
SW2SW1 7SEG1 7SEG2
ON
OFF
1 2 3 3654 7 8 21 54 76 8
SW3 SW4
1 2 73 4 5 6 8
SW5
1 2 73 4 5 6 8
SW6
SW7
SW8
SW9
LED3LED1 LED2
CNV
J13J11 J12 J15J14
Terminalblock
Tho-R1
Tho-D1
Tho-S
Tho-A
Tho-R2
Tho-R3
Tho-R4
Tho-SC
Tho-H
Tho-P1
Tho-C1
Circuit
breaker
A1 B1
A2 B2
PC
(RS232C)
YEWH
52X1-2
52X1-1
F(4A)
F(4A)
BETWEENINDOORUNITANDOUTDOORUNIT,BETWEEN
OUTDOORUNITSONTHESAMEREFRIGERANTLINE.
BETWEENOUTDOORUNITSONTHEDIFFERENT
REFRIGERANTLINES.
GN
RD
WH
BL
BL
BL
YE
YE
RD
BK
RD
WH
BL
WH
OR
YE
BL
GN
PK
WH
OR
YE
BL
GN
PK
BK
RD
BK
RD
RD
BL
OR
YE
WH
RD
BL
OR
YE
WH
RD
BL
OR
YE
WH
BK
BK
BK
BK
BK
BK
BK
BK
BK
WH
WH
WH
WH
BR
BL
BL
BL
BL
BK
BK
BK
BK
EEVH1
CNA3 CNA1
CNX1CNI1
CNI2WH
YE
BK
Earthleakage
breaker
(Impulse
withstandingtype)
52X1-4
52X1-3
GY
GY
52X1-3
52X1-4
R1-1R1-2
J16
RD
BL
RD
RD
WH
L1-2
WH
WH
RD
RD
RD
RD
BK
WH
RD
RD
WH
BL
RD
RD
WH
BL
BK
YE/GN
EEVSC
RD
BL
OR
YE
WH
CNEEV4YE
YE
CN15
BK
CN16
Tho-R5
Tho-R6
BK
BK
20SL
BL
20S3
BL
CNN12GY CNN5BK
CNDC1 CNDC2
M M MM M
U(Red) V(White)
W(Blue)
M
t° t° t° t° t°
MS
3〜
t° t° t°t° t° t°
Addresssettingswitch(master・slave)
SW4-5 Spare
SW5-1
SW5-2
SW5-3
SW4-8
SW4-7
SW4-6
ON
OFF
ON
OFF
TrialoperationON
OFF
SW4-1〜4 Modelsetting
Spare
Regularoperation
Trialoperationmode/cooling
Trialoperationmode/heating
Pumpdownoperation
Regularoperation
Addresssettingswitch(master・slave)
Fuse
Compressormotor
F
Crankcaseheater
EEVH1,2,3
EEVSC
CH1
CM1 Highpressuresensor
LowpressuresensorCNA-Z PSL
CT1
PSH
SW2
inspectionLEDreset
Autobackupoperation
Regularoperation
SW3-1
SW3-2
OFF
ON
)stigid2(.oNtinuroodtuoWSgnittessserddA
SW1
Defrostrecovertemp
Defroststarttemp
Externalinputselectlevel/pulse
D.C.reactor
Printedwiringboard(PCB)PWB1〜3
C1-1,2
IPM
)tlov(ledomputeS
Inspection(Red)LED1
LED2
LED3
J11,12
J13
J14
J15
)tigid1(.oNtinuroodtuoWSgnittessserddA
)neerG(lamroN
Service(greenforservice)
SV1 Solenoidvalve(CM1:bypass)
J16
L3 D.C.reactor
FMC1 FanforIPM
SV6 Solenoidvalve(oilseparatorCM1)
SV11 Solenoidvalve(gasbypass)
Connector
Currentsensor
Electrolyticcapacitor
DM1 Diodemodule
Expansionvalveforheating
ExpansionvalveforSC
BlowermotorFMo1,2
Intelligentpowermodule
gnihsalF-)wolleY(lamroNLED1(INV)
L1-1,2
Rushcurrentsuppressionresistor
R1-1〜1-4
SpareSW3-3
Forcedcooling/heating
Checkoperation
SW3-7 ON
OFF
SW3-5
OFF
ON
Regularoperation
Regularoperation
SpareSW3-6
SpareSW5-4
SW5-5
OFF
ON
SpareSW5-6~8
Hi-COPcombinationmodeSW6-3
SW3-8 Spare
SpareSW3-4
Powertransistorthermistor
7-segmentindicate(ten'splace)
Tho-P1
7-segmentindicate(unit'splace)
Tho-D1
Tho-H
SW8
SW9
TB1,2
4-wayvalve
Suctionpipethermistor
Tho-A
Tho-R3
)telni(rotsimrehtregnahcxetaeH
7SEG1
7SEG2
Tho-R4
Tho-S
Tho-SC
20S1
)noitacidni noitcnuf(.D.E.Ltnemges-7
)noitacidni atad(.D.E.Ltnemges-7
52X1-1〜1-4
SolenoidforCM
Tho-R1 )tsuahxe(rotsimrehtregnahcxetaeH
Terminalblock
Externalairthermistor
Tho-C1 Under-domethermistor
Dischargepipethermistor
Sub-coolingcoilthermistor2
)tsuahxe(rotsimrehtregnahcxetaeHTho-R2
)telni(rotsimrehtregnahcxetaeH
Highpressureswitch(forprotection)63H1-1
Sub-coolingcoilthermistor1
Dataclear/insertSW7
Colormark
BK Black
BL
BR
GN
GY
OR
Blue
Brown
Green
Gray
Orange
RD
WH
YE
Red
White
Yellow
PK Pink
Yellow
YE/GN
/Green
Mark Color
Meaningofmarks
PartsnameMark PartsnameMark PartsnameMark PartsnameMark
t° t°
Tho-R5
)telni(rotsimrehtregnahcxetaeHTho-R6
)tsuahxe(rotsimrehtregnahcxetaeH
4-wayvalve
20SL
Heatrecoveryunit
4-wayvalve
20S3
SpareSW6-1,2,4
OFF
ON
Standardmode
Superlinkcommunication
Superlinkcommunication