–11–
COOL/HEAT/DRY/FAN mode operation
Airflow direction adjustment procedure. Page 12
Point the remote control toward the air-conditioner, and
Press the MODE select button.
Move the [ mark] to the required operation position.
(Cool), (Heat), (Dry), (Fan)
Press the ON/OFF button.
Press the TEMP button.
Press or button for the preferred temperature.
Recommendation
4
3
To stop: Press the ON/OFF button.
In case air is not blown out, when starting the heating operation.
Page 21
The operation program can also be set or changed when
the air-conditioner is not in operation.
NOTE
2
1
Air-conditioner operable temperature setting
Use within the following operational range. Operating outside of this range may result in the protection devices being activated,
preventing the unit from working.
Cooling operation Heating operation
Outside temperature
Approximately -15 °C to 46 °C Approximately -15 to 24 °C
Inside temperature
Approximately 18 to 32 °C Approximately 15 to 30 °C
Below approximately 80%
The long-term use of the unit with a humidity level
Inside humidity
exceeding 80% may result in condensation forming
on the surface of the indoor unit, leading to water drips.
Characteristics of HEAT mode operation
Mechanism and capacity of HEAT mode operation
Mechanism
The unit draws heat from the cold outside air, transfers it to indoors and heats the room. As a characteristic of heat pump system, the
heating capacity reduces when the outside air temperature gets colder.
It may take some time to supply hot air after turning on the air-conditioner.
If the outside temperature becomes extremely low, it would be better to use an additional source of heating.
Defrosting
If the outside temperature becomes low and humidity is high, the heat exchanger in the outdoor unit may frost over, which prevents
efficient heating.
If this happens, the automatic defrost function is activated and during defrosting the heating operation stops for 5 to 15 minutes
during defrosting.
Both indoor and outdoor fans stop and the RUN light blinks slowly (1.5 sec. ON, 0.5 sec. OFF) during defrosting.
The outdoor unit may give off some steam during defrosting. This is to help the defrosting process and is not a defect.
The HEAT operation resumes as soon as defrosting has been completed.
Press the FAN SPEED button
Set the fan speed as preferred.
RLC012A007A_EN_001-024 4/8/14, 17:4011

Other manuals for Mitsubishi Heavy Industries SKM20ZSP-S

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Mitsubishi Heavy Industries SKM20ZSP-S and is the answer not in the manual?

Mitsubishi Heavy Industries SKM20ZSP-S Specifications

General IconGeneral
BrandMitsubishi Heavy Industries
ModelSKM20ZSP-S
CategoryAir Conditioner
LanguageEnglish

Related product manuals