EN-18
ON-TIMER + OFF-TIMER operation
The timer operations of the combination of ON and OFF-TIMER.
Example: Present time is 21:00. The air-conditioner running.
When it is preferred to stop at 22:30, and then start operation at 8:00, near the set
temperature.
1 OFF-TIMER operation setting
Set by the procedures on page 16. Set to
2 ON-TIMER operation setting
Set by the procedures on page 17. Set to
Timer light (yellow) on the unit will light when the setting is completed.
The set time will be displayed on the remote control. The display will change
depending on the operational status.
Comfort Start-up
In ON-TIMER operation, the unit starts the operation a little earlier, so
that the room can approach optimum temperature at ON time. This is so
called “Comfort start-up”.
x Mechanism
The room temperature is
checked 60 minutes before
the ON time. Depending on
the temperature at that time,
the operation starts 5 to 60
minutes before the timer is at
ON.
x The function is available
for COOL, HEAT and DRY
operation mode (including
AUTO).
SLEEP TIMER
In COOL operation
(Stop) Operation starts
Check the room
temp. 60 mins. before.
Set time
When SLEEP TIMER is selected, the set temperature is automatically
adjusted after a while, ensuring that the room is not too cold during cool-
ing or too warm during heating.
x During cooling : The preset temperature is lowered by 1 °C at the start
of SLEEP operation (when the timer is set). After that, the temperature
goes up by 1 °C every an hour to become 1 °C higher than the present
temperature.
x During heating: The preset temperature is lowered by 1 °C at the start
of SLEEP operation (when the timer is set). After that the temperature
becomes 3 °C lower in an hour and 6 °C lower in two hours than the
present temperature.
(Operation)
Set temperature
First the air-conditioner starts running with ON-TIMER.
After the air-conditioner stops running with OFF-TIMER.
First the air-conditioner stops running with OFF-TIMER.
After the air-conditioner starts running with ON-TIMER.
How to cancel
Press the CANCEL or ON/OFF button to turn off the timer display.
Changing of set time
Set a new time by using the OFF-TIMER or ON-TIMER button.
x The air-conditioner stopping.
x The air-conditioner running.
x Timer operation can be set only for next 24 hours.
NOTE
RFB012A009F_EN.indd 18 4/25/2020 9:30:14 PM

Other manuals for Mitsubishi Heavy Industries SRC25ZS-W2

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Mitsubishi Heavy Industries SRC25ZS-W2 and is the answer not in the manual?

Mitsubishi Heavy Industries SRC25ZS-W2 Specifications

General IconGeneral
BrandMitsubishi Heavy Industries
ModelSRC25ZS-W2
CategoryAir Conditioner
LanguageEnglish

Related product manuals