3 - 15 3 - 15
MELSEC-Q
3 OUTPUT MODULE SPECIFICATIONS
3.14 QY80 Transistor Output Module (Source Type)
Type
Specifications
Transistor output module (Source Type)
QY80 Appearance
Number of output points 16 points
Isolation method Photocoupler
Rated load voltage 12-24VDC (+20/-15%)
Maximum load current 0.5A/point, 4A/common
Maximum inrush current 4A, 10ms or less
Leakage current at OFF 0.1mA or less
Maximum voltage drop at ON 0.2VDC (TYP.) 0.5A, 0.3VDC (MAX.) 0.5A
Response time
OFF to ON 1ms or less
ON to OFF 1ms or less (rated load, resistive load)
Surge suppressor Zener diode
Fuse 6.7A (unchangeable) (fuse capacity: 50A)
Fuse blown indicator
Provided (When a fuse blows, LED turns on and a signal is output to the
CPU module.) 1
External supply
power
Voltage 12-24VDC (+20/-15%) (ripple ratio within 5%)
Current 20mA (at 24VDC)
Dielectric withstand voltage 560VAC rms/3 cycles (altitude 2000m)
Insulation resistance 10M or more by insulation resistance tester
Noise immunity
By noise simulator of 500Vp-p noise voltage, 1 s noise width
and 25 to 60Hz noise frequency
First transient noise IEC61000-4-4: 1kV
Protection degree IP2X
Common terminal arrangement 16 points/common (common terminal: TB17)
Number of occupied I/O points 16 points (I/O assignment is set as a 16-point output module.)
Operation indicator ON indication (LED)
External connections 18-point terminal block (M3 6 screws)
Applicable wire size 0.3 to 0.75mm
2
core (2.8mm OD max.)
Applicable crimping terminal R1.25-3 (Sleeved crimping terminals cannot be used.)
Internal current consumption
(5VDC)
80mA (TYP. all points ON)
Weight 0.17kg
External connection Terminal block No. Signal name
TB1 Y00
TB2 Y01
TB3 Y02
TB4 Y03
TB5 Y04
TB6 Y05
TB7 Y06
TB8 Y07
TB9 Y08
TB10 Y09
TB11 Y0A
TB12 Y0B
TB13 Y0C
TB14 Y0D
TB15 Y0E
TB16 Y0F
TB17 COM
TB18 0V
1: Fuse blown is not detected when the external power supply is shut off.
0
1
2
3
4
5
6
7
8
9
A
B
C
D
E
F
COM
QY80
12VDC
24VDC
0.5A
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
+-
FUSE
01234567
8 9ABCDEF
0
1
2
3
4
5
6
7
8
9
A
B
C
D
E
F