150
-
'11 • SCM-SM-110
ColorMark
BK
Color Marks
Black
BL Blue
BR Brown
ColorMark
RD Red
WH White
RD
CNW0
BL
WH
RD
X1
3
UH
BR
WH
CNM3
C
WH
1
F3.15A
1
3
X6
MH
BK
BL
5 7
L
RD
9
X3
X2
5
BK
BK
CNB WH
1 3
1
3
TB1
220240V
LED2
SW2
SW6
SW5
SW7
LED3
F3.15A
YGN
TB2
X
Y
WH
BK
Trl
RD
RD
BR
BR
BK
CNW2
19V
24V
1 2 3 4 5
CNJ
WH
BL
P
BR
OR
RD
M
LM
WH
CNF1
CNR
3
1
WH
X4
CNI
BL
WH
CNW1
M
1
XR1
XR2
XR3
XR4
Option
1
2
3
4
5
6
+12
CNT
BL
Control PCB
5
LED4
SW1
LED2 LED3
AMP
SW4
CNB2
WH
CNB
1 2 3 4
CNN Y
5 6 1 2
BK
CNH
Th -R1
Th -ATh -R2
t t
Th -R3
t t
I
I
I
I
BK
BK
BK
BK
WH
RD
Receiver PCB
Receiver PCB
Capacitor for FMI
CFI 1
FMI 1
TransformerTrl
SW2
ConnectorCNBޓ Z
TB1
Relay for FMX1ޓ 3,6
SW5
Operation check, Drain motor test run
SW7-1
FuseF
Thl -R1,2,3
Thl -A
Thc
LED3
LED2
Relay for DMX4
TB2
Fan motorwith thermostat
Indication lamp
Green-Normal operation
Indication lampRed-Inspection
Remote controller communication address
Plural units MasterSlave setting
Terminal block
ާPower source㧕㧔غmark
Terminal blockާSignal line㧕㧔غmark
ThermistorާRemote controller
ThermistorާReturn air
ThermistorާHeat exchanger
LM
Louver motor
SW6
Model capacity setting
7-segment display
Switches for setting
SW1
LED2
Back-up switchOperationStop
SW4
Indication lamp Green-Normal operation
LED3
Indication lamp Yellow-TimerInspection
LED4
BK
BK
BK
BK
XR5Remote operation input :
Operation
Heating
Compressor ON
Inspection
volt-free contact
Remote
controller
C
2
Earth
Power source line
Signal line
1 2
3
indoor unit and outdoor unit
Connecting line between
P Pink
OR Orange
Remote
Thc
TB2
Wired specification
Wireless specification
X
Y
X
Y
t
controller
WH
YGN YellowGreen
Y Yellow
CF
I
1
FMI 1
CNFI 1
WH
Notes 1. indicates wiring on site.
ޓޓ 2. See the wiring diagram of outside unit about the line between
indoor unit and outdoor unit.
YGN
ޓޓ 4. Do not put remote controller line alongside power source line.
OR
OR
When wired remote controller are used
onlywireless type
It is necessary to remove the line that is
connected to the receiver.
Remove signal line connected to the receiver
from primary side of terminal blockX,Y.
ATTENTION
ޓInsulate with tape the removed line.
The LED of that removed connector will
not be able to make any indication.
Ԙ
ԙ
)'06+6.'..
)'06+6.'+05'46
)'06+6.'47)'06+6.'/#:
ޓ 3. Use twin core cable0.3mm at remote controller line. Refer to page 30
ޓ of remote controller in case that the total length is more than 100m.
2
(5) Ceiling suspended type (FDEN)
Model FDEN50VD
A
PFA003Z819

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Mitsubishi SCM45ZJ-S and is the answer not in the manual?

Mitsubishi SCM45ZJ-S Specifications

General IconGeneral
BrandMitsubishi
ModelSCM45ZJ-S
CategoryAir Conditioner
LanguageEnglish

Related product manuals