Up/down air scroll Left/right air scroll
Thick line : moves quickly
Thin line : moves slowly
Stops at this position
for 5 seconds.
In COOL, DRY and FAN operation In HEAT operation In COOL, DRY and FAN operation In HEAT operation
Left louver Right louver
Stops at this position
for 5 seconds.
Activating both up/down air swing and left/right air swing at the same time results in a multi-directional air flow.
S
SRF series
Control the flap by AIRFLOW
(UP/DOWN) button on the wireless remote controller.
(a) Flap
Each time when you press the AIRFLOW
(UP/DOWN) button the mode changes as follows.
(b) Swing
1)
Swing flap
Flap moves in upward and downward directions continuously.
(c) Memory flap (Flap stopped)
When you press the AIRFLOW button once while the flap is operating, it stops swinging at the position. Since this angle is mem-
orized in the microcomputer, the flap will automatically be set at this angle when
the next operation is started.
(d) When not operating
The flap returns to the position of air flow directly below, when operation has stopped.