1-39
1.2.4 Piping system
Model SRK35GZ-L1
Heat exchanger
Strainer
Service valve (Liquid)
Flare connecting
Service valve (Gas)
Room
temp.
thermistor
Piping (Gas)
Ø12.7
Piping (Liquid)
Ø6.35
Flare connecting
Check
joint
4way valve
Discharge temp.
thermistor
Suction
Capillary tube
Check valve
Heat exchanger
Heat exchanger
thermistor
Outdoor air
temp. thermistor
Compressor
Accumulator
Discharge
Heat
exchanger
thermistor
Cooling cycle
Heating cycle
Indoor unit Outdoor unit
Outdoor unitIndoor unit
Room temp.
thermistor
Heat
exchanger
Flare connecting
Piping
(Gas)
ø9.52
Heat
exchanger
thermistor
Piping
(Liquid)
ø6.35
Check joint
4 way valve
Service valve (Liquid)
Flare connecting
Discharge temp.
thermistor
Cooling cycle
Heating cycle
Outdoor air
temp. thermistor
Heat
exchanger
Heat exchanger
thermistor
Compressor
Capillary tube
Strainer
Accumulator
Service valve
(Gas)
Model SRK25GZ-L1