- 7 -
1 - 12 KHz
0.1 - 400 Hz
Digital: 0.01%
Analog: 0.4%
0.01 HZ with computer of PLC control, 0.1 Hz with keypad control with frequency
above 100 Hz
0 - 5, 0 - 10V, 4 - 20mA, 10K Potentiometer
Optional card: Bi-polar ± 5 or ±10 Vdc command available. (Specify bi-polar
command signal range)
Programmable between 30% - 200%
2 separate programmable ACCEL/DECEL times
0.1 - 3600 SEC with 2 S-curves
Programmable DECEL or free run to stop
150% for up to 1 minute
Braking Torque
200V & 400V
Class
Standard braking torque = 20%
100% braking torque available with addition of optional resistors (plus braking
transistors on units rated 15HP and above)
18 patterns, one curve programmable
IGBT transistors in a sine-coded PWM (Pulse Width Modulated) firing scheme
Approximately 200% of unit rated current
150% for 1 minute
Programmable electronic thermal overload relay
200V Class: DC bus exceeds 427V
400V Class: DC bus exceeds 854V
200V Class: DC bus voltage drop < 200V
400V Class: DC bus voltage drop < 400V
Programmable 0~2 seconds: unit can be restarted via speed search
Motor coast to stop at blown fuse
Protected by thermister/thermostat
Via charge LED
Start -up Standard on all units
Running Standard on all units
Operation Signal Forward/Reverse operation; individual command
Multifunction
Input Selection
Standard: 3 dry contact inputs only
Optional: 120 Vac interface card
Multifunction
Output
1 output 35Vdc, 50mA maximum
Fault Output 250 Vac 1A, 30 Vdc 1A maximum
Frequency reference bias/gain, upper lower limit, auto/manual torque boos, frequency
meter gain calibration, auto reset attempt, skip frequency, S-curve: ACCEL/DECEL,
current limit, carrier frequency adjust (1 - 12 KHz), communication link function,
energy saver, vibration control, 7 process timers
Frequency command, output frequency, output current, output voltage, P-N bus
voltage, rotation direction, engineering units
Analog output (0-10V), possible to select output frequency, setting frequency, output
voltage and P-N bus voltage
NEMA 1 (IP20) standard, NEMA 4 /4X also available (up to 10HP)
Indoor (protected from gas and dust) 3,300 feet (without derating). Use in an
enclosure with filtered forced ventilation, or if standalone, in a clean pollution-free
environment
Enclosed: -10º C to 40º C (14º F to 104º F)
Chassis: -10º C to 50º C (14º F to 122º F)
-10º C to 50º C (14º F to 122º F)
0 - 95% non-condensing
0.5G
EMC 89/336/EEC
Approvals
UL listed and Canadian UL (cUL) listed, CE Approved
EMC
Environmental
Conditions
Instantaneous Overcurrent
Overload Capacity of Drive
Output
Signal
Enclosure
Humidity
Digital Operator Monitor
Built-in Functions
DC Bus Protection
Power Charge Indication
Vibration
Output Power Circuit
V/f Pattern
Overvoltage
Storage Temperature
Input
Signal
Analog Output Monitor
Location and Altitude
Ambient Temperature
Momentary Power Loss
Operation Conditions
Frequency Control Range
Frequency Accuracy
Frequency Resolution
Motor Overload Protection
Frequency Setting Signal
ACCEL/DECEL Time
Undervoltage
Heat Sink Fin Overheat
Ground Fault
Protection
Control CharacteristicsProtection Functions
Carrier Frequency
Stall Prevention
Starting Torque