Page #18 background image
Page 17
Problem Possible Causes Solution
The unit is not
working
Power failure
Wait for the power to be
restored
The power is turned off Turn on the power
The fuse is burned out Replace the fuse
Remote control batteries are
dead
Replace batteries
The Unit’s 3-minute protection
has been activated
Wait three minutes after
restarting the unit
Timer is activated Turn timer off
The unit starts and
stops frequently
There’s too much or too little
refrigerant in the system
Check for leaks and
recharge the system with
refrigerant.
Incompressible gas or
moisture has entered the
system.
Evacuate and recharge the
system with refrigerant
The compressor is broken Replace the compressor
The voltage is too high or too
low
Install a manostat to
regulate the voltage
Poor heating
performance
The outdoor temperature is
lower than 7°C (44.5°F)
Use auxiliary heating
device
Cold air is entering through
doors and windows
Make sure that all doors
and windows are closed
during use
Low refrigerant due to leak or
long-term use
Check for leaks, re-seal
if necessary and top off
refrigerant
Indicator lamps
continue flashing
The unit may stop operation or continue to run safely. If
the indicator lamps continue to flash or error codes appear,
wait for about 10 minutes. The problem may resolve itself.
If not, disconnect the power, then connect it again. Turn
the unit on.
If the problem persists, disconnect the power and contact
your dealer or qualified service professional.
Error code appears in
the window display
of indoor unit:
E0, E1, E2…
P1, P2, P3…
F1, F2, F3…
NOTE: If your problem persists after performing the checks and diagnostics above, turn off your
unit immediately and contact your dealer or qualified service professional.
Troubleshooting

Other manuals for MrCool DIY Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the MrCool DIY Series and is the answer not in the manual?

MrCool DIY Series Specifications

General IconGeneral
Phase1
TypeMini-Split
Cooling Capacity12, 000 - 36, 000 BTU/h (varies by model)
Heating Capacity12, 000 - 36, 000 BTU/h (varies by model)
SEER RatingUp to 22
Power Supply115V/230V (varies by model)
RefrigerantR410A
Wi-Fi ControlYes
FeaturesAuto-restart
Voltage115V/230V (varies by model)
HSPF RatingUp to 10
Outdoor Unit Noise Level (dB)50 - 60 dB (varies by model)
Indoor Unit WeightVaries by model, approximately 20-25 lbs