Page #8 background imageLoading...
Page #8 background image
Unit
Specifications
and Features
Page 7
COOL mode HEAT mode DRY mode
Room Temperature
17°C - 32°C
(63°F - 90°F)
0°C - 30°C
(32°F - 86°F)
10°C - 32°C
(50°F - 90°F)
Outdoor
Temperature
-15°C - 30°C
(5°F - 86°F)
0°C - 50°C
(32°F - 122°F)
-15°C - 50°C
(5°F - 122°F)
To further optimize the performance of your unit, do the following:
Keep doors and windows closed.
Limit energy usage by using TIMER ON and TIMER OFF functions.
Do not block air inlets or outlets.
FOR UNITS WITH
AUXILARY ELECTRIC
HEATER
Achieving Optimal Performance
Optimal performance for the COOL, HEAT, and DRY modes can be achieved in the following temperature
ranges. When your air conditioner is used outside of these ranges, certain safety protection features
will activate and cause the unit to perform less than optimally.
Inverter Split Type
When outside
temperature is below 0°C
(
32°F ), we strongly
recommend keeping the
unit plugged in at all
times
s
to ensure smooth
ongoing performance.

Other manuals for MrCool DIY Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the MrCool DIY Series and is the answer not in the manual?

MrCool DIY Series Specifications

General IconGeneral
BrandMrCool
ModelDIY Series
CategoryAir Conditioner
LanguageEnglish

Related product manuals