Appendix B
B-10Intel RAID
Degraded RAID Array
A RAID 1, RAID 5 or RAID 10 volume is reported as degraded when one of its hard
drive members fails or is temporarily disconnected, and data mirroring is lost. As a
result, the system can only utilize the remaining functional hard drive member. To
re-establish data mirroring and restore data redundancy, refer to the procedure below
that corresponds to the current situation.
Missing Hard Drive Member
Make sure the system is powered o󰘯.
Reconnect the hard drive.
Reboot the system to Windows; the rebuild will occur automatically.
Failed Hard Drive Member
Make sure the system is powered o󰘯.
Replace the failed hard drive with a new one that is of equal or greater capacity.
Reboot the system to Intel RAID Option ROM by press <Ctrl> and <I> keys
simultaneously during the Power-On Self Test (POST).
1.
2.
3.
1.
2.
3.
Select the port of the destination disk for rebuilding, and then press ENTER.4.
RAID Volumes
ID Name Level Strip Size Status Bootable
0 Volume0 RAID 1(Mirror) N/A XXX.XGB Degraded Yes
Physical Disks:
Port Device Model Serial # Size Type/Status(Vol ID)
1 XXXXXXXXXXXXX XXXXXXXXXXXXX XXX.XGB
Member Disk (0)
2 XXXXXXXXXXXXX XXXXXXXXXXXXX XXX.XGB
Member Disk (0)
Press <CTRL-I> to enter Con󰘰guration Utility..
DISK / VOLUME INFORMATION
[ ]
4. Recovery Volume Options
4. Recovery Volume Options
5. Exit
RAID Volumes :
None de󰘰ned.
Physical Devices :
Port Device Model Serial # Size Type/Status (Vol ID)
1 XXXX-XXXXXXXX XXXXXXXXXXXXXX XXX.XGB Non-RAID Disk
2 XXXX-XXXXXXXX XXXXXXXXXXXXXX XXX.XGB Non-RAID Disk
[ ↑↓] - Select [ESC] - Exit [ENTER] - Select Menu
1. Create RAID Volume
2. Delete RAID Volume
“Degraded” volume and disk available for rebuilding detected. Selecting
a disk initiates a rebuild. Rebuild completes in the operating system.
[ ]
DEGRADED VOLUME DETECTED
Select the port of the destination disk for rebuilding (ESC to exit):
[ ↑↓] - Previous/ Next [ENTER] - Select [ESC] - Exit
Port Drive Model Serial # Size
1 XXXX-XXXXXXXX XXXXXXXXXXXXXX XXX.XGB
[ ]
MAIN MENU

Table of Contents

Other manuals for MSI Z87-G41 PC Mate

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the MSI Z87-G41 PC Mate and is the answer not in the manual?

MSI Z87-G41 PC Mate Specifications

General IconGeneral
BrandMSI
ModelZ87-G41 PC Mate
CategoryMotherboard
LanguageEnglish

Related product manuals