EasyManuals Logo
Home>mspa>Hot Tub>C-BE041

mspa C-BE041 User Manual

mspa C-BE041
17 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #15 background imageLoading...
Page #15 background image
15
DISPOSAL AND ENVIRONMENTAL PROTECTION
This marking indicates that the product should not be disposed of with other household waste. To prevent possible harm to the
environment or human health from uncontrolled waste disposal, recycle the product responsibly to promote the sustainable reuse of
material resources. Information on disposal can be obtained from your local authorities.
To return your used device, please use the return and collection systems or contact the retailer where the product was purchased for
environmentally safe recycling.
TROUBLESHOOTING
LED READING CAUSE SOLUTION
- - -
F0
F1
Contact local MSpa Service Center
Contact local MSpa Service Center
Change the water
Contact local MSpa Service Center
Clean the parts and tubes that the water goes through
1. Add more water to the minimum line
2. Clean the parts and tubes that water goes through
3. Contact local MSpa Service Center
ERROR CODE CHART
Signal wire is loose
Communication failed
Water temperature is below 0°C (32°F) or exceeds 50°C (122°F)
Temperature sensor failure
F1 immediately shows after pressing FILTER , HEATING
F1 shows 15s after pressing FILTER, HEATING
PROBLEM CAUSE SOLUTION
NO DISPLAY ON THE
CONTROL PANEL
SPA LEAKING
NOT HEATING
PROPERLY
Change a socket or repair the socket before use
Reset the PRCD by following the PRCD Testing section
Contact local MSpa Service Center
Contact local MSpa Service Center
Tighten the in&outlet connection
Close the drainage valve. Contact the MSpa Service Center,
if spa is still leaking
Repair the leaking hole/split with the repair kit material
Set a higher temperature
Clean or replace the filter cartridge
Add more water to the minimum line
Contact local MSpa Service Center
Refer to the "FILTER PUMP DOES NOT WORK" section
Reset the heater
Power socket failure
PRCD is off
Press the Reset button, controller is not displayed
PRCD broken
Spa in&outlet connection not securely tight
Drainage valve is not closed completely
Water leaks from the spa pool body
Temperature set too low
Dirty filter cartridge
Water level is not at the minimum water line
Heater failure
Filter pump DOES NOT WORK
Temperature protection switch trip off

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the mspa C-BE041 and is the answer not in the manual?

mspa C-BE041 Specifications

General IconGeneral
Brandmspa
ModelC-BE041
CategoryHot Tub
LanguageEnglish