USER GUIDE AND TERMINAL BLOCK
SPECIFICATIONS
NI PXIe-4302/4303 and
TB-4302/4302C
32 Ch, 24-bit, 5 kS/s or 51.2 kS/s Simultaneous Filtered Data
Acquisition Module
This document explains how to install, configure, and set up the NI PXIe-4302 and
NI PXIe-4303 (NI PXIe-4302/4303) simultaneous filtered modules with the TB-4302 and
TB-4302C terminal blocks. Driver support for the NI PXIe-4302/4303 was first available in
NI-DAQmx 15.1. For the list of devices supported by a specific release, refer to the NI-DAQmx
Readme, available on the version-specific download page or installation media.
Note The keying of these terminal blocks prevents them from connecting to other
modules that could be damaged by the voltage present on the terminal block.
However, you should only use these terminal blocks with their supported modules.
Contents
Electromagnetic Compatibility Guidelines .............................................................................. 2
What You Need to Get Started ................................................................................................. 3
Installation ................................................................................................................................ 3
Install the Software ........................................................................................................... 3
Unpack and Install the Module......................................................................................... 4
Connect the Signals .......................................................................................................... 5
Install the Terminal Block ................................................................................................ 8
Confirm NI PXIe-4302/4303 Module Recognition.......................................................... 10
Run Test Panels ................................................................................................................ 11
Take an NI-DAQmx Measurement .................................................................................. 11
NI-DAQmx Channels and Tasks.............................................................................. 11
Configure a Task Using the DAQ Assistant in MAX .............................................. 11
Use Your NI PXIe-4302/4303 Module in an Application................................................ 12
Programming Examples ........................................................................................... 12
Terminal Block Removal..........................................................................................................13
Module Removal ...................................................................................................................... 14
Create a Simulated Device .......................................................................................................15