INTRODUCTION
Torque-Standardtorquedataforhydraulicconnections
Generalinformation
•
Hydraulicconnectionsrequireaminimumassemblytorqueinordertoprovidezeroleakageatratedpressurewith
adequatefatigueresistance.Over-torquingofahydraulicconnectioncanalsoleadtoleakageorfailure.Forsome
connections,NEWHOLLANDrequiresadifferenttorquevaluethanislistedintheISOandSAEstandards.
•
Thetorquevaluesinthisdocumentshouldbeusedwheneverpossibleorapplicable.
NOTICE:Alwaysfollowtheinstructionsinthismanualforspecictorquevalueswhenyouservicecomponents.
Theinformationinthissectionisforgeneralguidanceonlywhenaprocedurecontainsnospecictorquevalue.
Tolerance
•
Thetoleranceforalltorquevaluesis±10%.Thistolerancemustincludeallassemblyvariation,notonlythetorque
wrenchrepeatability.
Lubrication
Applicationofgreaseorotherlubricantstohydraulicconnectorsshouldbeavoided.Ifcleanhydraulicoilisalready
ontheconnection,itisnotrequiredtoremovetheoil.Generally,applicationofgrease:
•
Maycauseasignicantchangeinthetorquerequiredtoproperlytightentheconnection.
•
Mayreducetheconnection’sresistancetovibration.
•
Excessivegreasemaydisplaceanelastomersealduringtightening.
•
Greaseextrusionwhenconnectionistightenedmaybemistakenforleakage.
NEWHOLLANDproductsgenerallyuseO-RingBoss(ORB)connectorsthathaveTeon™-coatedO-rings,eliminat-
ingtheneedforO-ringlubricationduringinstallation.Forconnectionswhicharemadeintoaluminummanifoldsor
withstainlesssteelconnectors,itmayberequiredtoapplyalubricanttopreventgalling.
UseofLOCTITE®andotherthread-lockingcompoundsisprohibited.Thesecompounds:
•
Maycauseasignicantchangeinthetorquerequiredtoproperlytightentheconnections.
•
Reducetheserviceabilityofthejoint.
•
MaypreventtheO-ringfromproperlysealingifthecompoundgetsontheO-ring.