Robus 600-1000 – 3
Installation
This function enables start-up of the procedure for learning the devices connected to the Bluebus input and the HALT input of
the control unit of an automation. Important – To activate the device search, press “Start”.
This function enables the measurement of the distance between the Closing limit position and Opening limit position (length of
the gate leaf). This measurement is used by the control unit to censure the precise calculation of the points (positions) at which
the gate leaf must start to decelerate during a manoeuvre and to determine the partial opening positions. To activate the posi-
tion search, press “Start”.
maximum opening
This function enables the display of the Opening limit position, after the relative learning procedure has been completed.
deceleration on opening
This function is expressed in metres. This enables programming of the precise point (position) at which the gate should start
decelerating before reaching the limit switch at the end of the Opening manoeuvre. After programming the required point, press
OK” to save the value.
partial open 1
This function is expressed in metres. During the opening manoeuvre this enables programming of the precise point (position) at
which the gate stops travel (partial open). After programming the required point, press “OK” to save the value.
partial open 2
This function is expressed in metres. During the opening manoeuvre this enables programming of the precise point (position) at
which the gate stops travel (partial open). After programming the required point, press “OK” to save the value.
partial open 3
This function is expressed in metres. During the opening manoeuvre this enables programming of the precise point (position) at
which the gate stops travel (partial open). After programming the required point, press “OK” to save the value.
deceleration on closing
This function is expressed in metres. This enables programming of the precise point (position) at which the gate should start
decelerating before reaching the limit switch at the end of the Closing manoeuvre. After programming the required point, press
OK” to save the value.
This function enables the user to delete the configuration of a control unit and the relative stored data, selecting items from a
series. These items are:
positions – enables deletion of all memorised positions;
bluebus devices – enables deletion of the configuration of the Bluebus devices and the HALT input;
function values – enables deletion of all values and settings of functions envisaged on the control unit;
all – enables the deletion of all data in the Control unit memory excluding the reserved parameters: series
, address, hard-
ware version
, software version, serial number.
Basic parameters
This parameter type is ON/OFF; the factory setting is “OFF”. This function enables the activation of automatic closure at the end
of an opening manoeuvre in the control unit of the automation. If the function is active (ON) the automatic closure manoeuvre
starts at the end of the wait time programmed in the function “pause time”.
If the function is not active (OFF) the Control unit operation mode is “semiautomatic”.
This parameter is expressed in seconds and can be set with a value from 0 to 250 sec.; the factory setting is 30 sec. This func-
pause time
automatic closure
data deletion
bluebus search
positions
position search
CONTROL UNIT FUNCTIONS

Other manuals for Nice Robus 1000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Nice Robus 1000 and is the answer not in the manual?

Nice Robus 1000 Specifications

General IconGeneral
BrandNice
ModelRobus 1000
CategoryGate Opener
LanguageEnglish

Related product manuals