Nilfisk C 120.3 / C 125.3 / C 130.1
19
Original Instructions
Type C 120.3 C 125.3 C 130.1
Electrical Specification
Rated voltage V 230 230 230
Rated frequency Hz 50 50 50
Rated power consumption kW 1,650 1,800 1,700
Current A 7.2 7.8 7.8
Protection class
Class I/
Class II
Class II Class II Class I
Protection degree IP xx IPX5 IPX5 IPX5
Hydraulic specification
Rated pressure MPa/bar 10/100 10.5/105 11.5/115
Max. pressure MPa/bar 12/120 12.5/125 13/130
Rated water flow l/min/l/h 5.8/350 5.8/350 6.3/380
Max. water flow l/min/l/h 8.6/520 8.6/520 7.3/440
Max. water inlet pressure Mpa/bar 1/10 1/10 1/10
Max. water inlet temperature °C 40 40 40
Max. water inlet temp. suction mode °C 20 20 20
Weight kg 8.9 9 15.8
Hand-arm vibration according to ISO 5349-1:
Standard nozzle m/s
2
< 2.5 ±1 < 2.5 ±1 < 2.5 ±1
Sound pressure level L
pA
in accordance with
ISO 3744
dB(A) 78 ±3 78 ±3 66.4 ±3
Guaranteed sound power level L
WA in
accordance with 2000/14/EC
dB(A) 92 92 84
10 Main Technical Data