Voice Alarm Multiplex 15889:F2 10/01/01
99
99
9
21
Notes:Notes:
Notes:Notes:
Notes:
1) All the above tone/messages sequences will repeat until they have been deselected through the annunciator
control point. Priority within each group of four is from top (highest priority) to bottom (lowest priority).
2) If a digitally-stored voice message fails, the AMG-1 will automatically switch to the primary evacuation tone and
will generate a trouble condition.
3) All pauses are 5 seconds long unless otherwise noted.
Table 3-1: AMG-1 Tone/Message Functions
(for AMG-1 addresses A32 through A29)
Audio Message
Generator DIP
Switch Settings
Annunciator Control Points
on ACM-16AT Address A01
AMG-1 at Address
Tone/Voice Message Group Functions
S6 S7 S8 A32 A31 A30 A29
Off Off Off P01 P05 P09 P13 VROM A
Off Off Off P02 P06 P10 P14 VROM B
Off Off Off P03 P07 P11 P15 VRAM A
Off Off Off P04 P08 P12 P16 VRAM B
Off Off On P01 P05 P09 P13 3 Fast Whoops, Pause, VROM A
Off Off On P02 P06 P10 P14 3 Hi/Low Tones, Pause, VROM B
Off Off On P03 P07 P11 P15 3 Yeows, Pause, VRAM A
Off Off On P04 P08 P12 P16 3 Slow Whoops, Pause, VRAM B
Off On Off P01 P05 P09 P13 3 Fast Whoops, Pause, VROM A, VROM B
Off On Off P02 P06 P10 P14 3 Hi/Low Tones, Pause, VRAM A
Off On Off P03 P07 P11 P15 3 Yeows, Pause, VRAM B
Off On Off P04 P08 P12 P16 Wail
Off On On P01 P05 P09 P13 3 Slow Whoops, Pause, VROM A
Off On On P02 P06 P10 P14 3 Hi/Low Tones, Pause, VROM B
Off On On P03 P07 P11 P15 Yelp
Off On On P04 P08 P12 P16 Wail
On Off Off P01 P05 P09 P13 3 Slow Whoops, Pause, VRAM A
On Off Off P02 P06 P10 P14 3 Hi/Low Tones, Pause, VRAM B
On Off Off P03 P07 P11 P15 Yelp
On Off Off P04 P08 P12 P16 Wail
On Off On P01 P05 P09 P13 3 Slow Whoops, Pause, VROM A
On Off On P02 P06 P10 P14 3 Hi/Low Tones, Pause, VRAM A
On Off On P03 P07 P11 P15 Boston Code
On Off On P04 P08 P12 P16 Horn
On On Off P01 P05 P09 P13 California Uniform Fire Code (10s Yelp, Pause)
On On Off P02 P06 P10 P14 California Uniform Fire Code (10s Fast Whoops, Pause)
On On Off P03 P07 P11 P15 3 Hi/Low Tones, Pause, VROM A, Pause
On On Off P04 P08 P12 P16 3 Slow Whoops, Pause, VRAM A, Pause
On On On P01 P05 P09 P13 Yelp
On On On P02 P06 P10 P14 Hi/Low Tones
On On On P03 P07 P11 P15 Slow Whoop
On On On P04 P08 P12 P16 NFPA Code (Three 470 Hz Tones, 1.5s Pause)