7
E3JM
Wiring
Connecting and Wiring
We recommend connecting a cable with a conductor cross-section
of 0.3 mm
2
and an outer diameter of 6 to 8 mm.
Be sure to firmly tighten the cover in order to maintain waterpr
oof
and dustpro
of properties. The screw
size of the conduit sockets is
shown in the following table.
When using the DC SSR output model, the total of the load current
for the Light-ON output (NO) and that for the Dark-ON (NC) should
be 100 mA max. If the total exceeds
100 mA, the load short-circuit
protection function will
be activated (this function will be reset when
the power of the Photoelectric Sensor is turned OFF).
Cable End Treatment
Recommended Crimp Terminal Dimensions
(Unit: mm)
Note: Use terminals with insulation tube (recommended crimp terminal: 1.25 to
3.5).
Others
Terminal Protection Cover (Provided)
The terminal protection cover is designed to improve safety by
maintaining the sensitivity properties of the product and by preventing
any contact with charged sections while it is being operated with the
mode set to the timer mode. Mount the product as shown in the
following diagram (mount the Through-beam Model on the Receiver
side).
Ambient Conditions (Installation Area)
The E3JM will malfunction if installed in the following places.
Places where the E3JM is exposed to a dusty environment.
Places where corrosive gases are produced.
Places where the E3JM is directly exposed t
o water, oil, or
chemicals.
Model Conduit socket thread size
E3JM-@ PF1/2
E3JM-@-G PG13.5
E3JM-@-US 1/2-14NPT
Round type Fork type
Power
source
Tc, Ta
Tb
Approx.
45 mm
Approx.
55 mm
Tightening nut (provided)*
Washer (provided)*
Rubber bushing (provided)*
Adjust the four wires to the same length when
the Ta output is to be used only. If both the Ta
and Tb outputs are to be used, treat them as
shown in the following diagram.
Recommended example
* These parts are not provided with models with a -US suffix.
10 max.
19 max.
3.6 dia. min.
7 max.7 max.
(After crimping)
10 max.
19 max.
3.6 dia. min.
7 max.7 max.
(After crimping)
Terminal protection cover
E3JM