Technical data
Product category Electronic Sphygmomanometers
Product Description Automatic Wrist Blood Pressure Monitor
Model (code) RS2 (HEM-6161-E)
Display LCD Digital Display
Cuff pressure range 0 to 299 mmHg
Blood pressure
measurement range
SYS: 60 to 260 mmHg
DIA: 40 to 215 mmHg
Pulse measurement range
40 to 180 beats / min.
Accuracy
Pressure: ±3 mmHg
Pulse: ±5% of display reading
Inflation Automatic by electric pump
Deflation Automatic rapid deflation
Measurement method Oscillometric method
Operattion mode Continuous operation
IP classification IP 22
Rating DC3 V 3.0 W
Power source 2 “AAA” alkaline batteries 1.5V
Battery life
Approximately 300 measurements (using new alkaline batteries)
Durable period (Service life)
5 years
Operating conditions
+10°C to +40°C / 15 to 90% RH (noncondensing) / 800 to 1060 hPa
Storage / Transport
conditions
-20°C to +60°C / 10 to 90% RH (noncondensing)
Weight
Approximately 85 g not including batteries
Dimensions
Approximately 84 mm (w) × 62 mm (h) × 21 mm (l) (not including the wrist
cuff
)
Measurable wrist
circumference
13.5 to 21.5 cm
Memory Stores up to 30 readings
Contents
Monitor, storage case, 2 “AAA” alkaline batteries, instruction manual
Protection against electric
shock
Internally powered ME equipment
Applied part Type BF (wrist cuff)
Maximum temperature of the
applied par
t
Lower than +48°C
EAN code 401567211111 0
Note
• These specifications are subject to change without notice.
• In the clinical validation study, K5 was used on 85 subjects for determination of diastolic blood
pressure.
• This monitor is clinically investigated according to the requirements of ISO 81060-2:2013.