EasyManuals Logo
Home>Omron>Power Supply>S8VS-06024

Omron S8VS-06024 User Manual

Omron S8VS-06024
38 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #3 background imageLoading...
Page #3 background image
S8VS
3
Specifications
Ratings/Characteristics
*1. Do not use an inverter output for the Power Supply. Inverters with an output frequency of 50/60 Hz are available, but the rise in the internal
temperature of the Power Supply may result in ignition or burning.
*2. For a cold start at 25°C. Refer to Engineering Data on page 18 for details.
*3. If the output voltage adjuster (V. ADJ) is turned, the voltage will increase by more than +15% of the voltage adjustment range. When adjusting
the output voltage, confirm the actual output voltage from the Power Supply and be sure that the load is not damaged.
*4. To reset the protection, turn OFF the input power for three minutes or longer and then turn it back ON.
*5. The range for compliance with EC Directives and safety standards (UL, EN, etc.) is 100 to 240 VAC (85 to 264 VAC).
Power ratings 15 W 30 W
Item Output voltage 5 V 12 V 24 V 5 V 12 V 24 V
Efficiency
With 100-VAC input 74% typical 79% typical 83% typical 74% typical 81% typical 85% typical
With 200-VAC input 73% typical 78% typical 80% typical 74% typical 80% typical 86% typical
Input
Voltage *1 100 to 240 VAC (allowable range: 85 to 264 VAC, 80 to 370 VDC *5)
Frequency *1 50/60 Hz (47 to 450 Hz)
Current
With 100-VAC input 0.45 A max., 0.34 A typical 0.9 A max., 0.66 A typical
With 200-VAC input 0.25 A max., 0.22 A typical 0.6 A max., 0.4 A typical
Power factor ---
Harmonic current regulation Conforms to EN61000-3-2
Leakage current
With 100-VAC input 0.5 mA max.
With 200-VAC input 1.0 mA max.
Inrush current *2
With 100-VAC input 17.5 A max., 14 A typical
With 200-VAC input 35 A max., 28 A typical
Output
Voltage adjustment range *3 10% to 15% (with V.ADJ)
Ripple noise voltage (at rated I/O) 60 mV max. 70 mV max. 60 mV max. 60 mV max. 90 mV max. 150 mV max.
Input variation influence 0.5% max. (at 85- to 264-VAC input, 100% load)
Load variation influence
(rated input voltage)
2.0% max. (5 V), 1.5% max. (12 V, 24 V), (with rated input, 0 to 100% load)
Temperature variation influence 0.05%/°C max.
Startup time
(at rated I/O) *2
With 100-VAC input 580 ms typical 530 ms typical 600 ms typical 500 ms typical 560 ms typical 560 ms typical
With 200-VAC input 340 ms typical 360 ms typical 400 ms typical 360 ms typical 380 ms typical 400 ms typical
Output hold time
(at rated I/O) *2
With 100-VAC input 39 ms typical 27 ms typical 28 ms typical 31 ms typical 22 ms typical 31 ms typical
With 200-VAC input 187 ms typical 134 ms typical 134 ms typical 174 ms typical 123 ms typical 140 ms typical
Additional
functions
Overload protection *2 The range for compliance with EC Directives and safety standards (UL, EN, etc.) is 100 to 240 VAC (85 to 264 VAC).
Overvoltage protection *2 Yes *4
Output voltage indication No
Output current indication No
Peak-hold current indication No
Maintenance forecast monitor indication No
Maintenance forecast monitor output No
Total run time monitor indication No
Total run time monitor output No
Undervoltage alarm indication Yes (color: red)
Undervoltage alarm output No
Parallel operation No (However, backup operation is possible. An external diode is required.)
Series operation
Models with 24-V output: Possible for up to 2 Power Supplies (with external diode)
Models with 5- or 12-V output: Not possible
Other
Operating ambient temperature Refer to the derating curve in Engineering Data. (with no icing or condensation)
Storage temperature 25 to 65°C
Operating ambient humidity 25% to 85% (Storage humidity: 25% to 90%)
Dielectric strength
3.0 kVAC for 1 min. (between all inputs and outputs; detection current: 20 mA)
2.0 kVAC for 1 min. (between all inputs and PE terminals; detection current: 20 mA)
1.0 kVAC for 1 min. (between all outputs and PE terminals; detection current: 20 mA)
Insulation resistance 100 MΩ min. (between all outputs and all inputs/ PE terminals) at 500 VDC
Vibration resistance 10 to 55 Hz, 0.375-mm single amplitude for 2 h each in X, Y, and Z directions
Shock resistance 150 m/s
2
, 3 times each in ±X, ±Y, and ±Z directions
Output indicator Yes (color: green)
EMI
Conducted
Emissions
Conforms to EN55011 Group1 Class B and based on FCC Class A
Radiated Emissions Conforms to EN55011 Group1 Class B
EMS Conforms to EN61204-3 high severity levels
Approved standards
UL 508 (Listing, Class2 Output: Per 1310)
UL 60950-1, UL 62368-1
CSA C22.2 No.107.1 (cUL) (Class2 Output: Per CSA C22.2 No.223)
CSA C22.2 No.60950-1 (cUR), No.62368-1
EN 50178, EN 60950-1, EN 62368-1
EAC mark, RCM mark
SEMI F47-0706 (With 200-VAC input)
Weight 160 g max. 180 g max.
Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.