4. Memory Preservation
This unit does not require memory preservation batteries. A
built-in memory power back-up system preserves the contents
of the memory during power failures and even when the unit is
unplugged. The unit must be plugged in order to charge the
back-up system.
The memory preservation period after the unit has been
unplugged varies depending on climate and placement of the
unit. On the average, memory contents are protected over a
period of a few weeks after the last time the unit has been
unplugged. This period is shorter when the unit is exposed to a
highly humid climate.
2. To initialize the unit
This device employs a microprocessor to perform various
functions and operations. If interference generated by an external
power supply, radio wave, or other electrical source results in
accident which causes the specified operations and functions to
operate abnormally.
To perform a result, please follow the procedure below.
1.Press and hold down the VIDEO-1 button, then press the
STANDBY/ON button.
2.After "clear" is displayed, the preset memory and each
mode stored in the memory, such as surround, are
initialized and will return to the factory setting.
3. Safety-check out
(Only U.S.A. model)
After correcting the original service problem, perform the
following safety check before releasing the set to the customer.
Connect the insulating-resistance tester between the plug of power
supply cord and screw on the back panel.
Specifications: 3.3Mohm+/-10% at 500V.
1. Replacing the fuses
This symbol located near the fuses indicates that the
fuse used is fast operating type. For continued protection against
fire hazard, replace with same type fuse. For fuse rating refer to
the marking adjacent to the symbol.
Ce symbole indique que le fusible utlise est a rapide.
Pour une protection permanente, n'untiliser que fusibles de
meme type. Ce darnier est la qu le present symbol est
appse.
CIRCUIT NO. PART NO. DESCRIPTION
F6901, 252198 or 8A-UL or
F6902
252261 8A-T/UL-ST2,Fuse
F901
252198 or 8A-UL or
252261 8A-T/UL-ST2,Fuse
HT-R500
SERVICE PROCEDURES

Other manuals for Onkyo HT-R500

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Onkyo HT-R500 and is the answer not in the manual?

Onkyo HT-R500 Specifications

Amplifier Section IconAmplifier Section
continuous average power output (FTC)100 watts per channel at 8 ohms
dynamic power output at 3 ohms230 watts × 2
dynamic power output at 4 ohms170 watts × 2
dynamic power output at 8 ohms115 watts × 2
total harmonic distortion0.08% at rated power
damping factor60 at 8 ohms
Input and Output Impedance IconInput and Output Impedance
digital input (optical 1, 2)0.5 Vp-p, 75 ohms
digital input (coaxial)0.5 Vp-p, 75 ohms
line (CD, VIDEO 1, 2, 3, TAPE)200 mV, 50 kohms
multichannel input (DVD FRONT L/C/R, SURR L/R)200 mV, 50 kohms
subwoofer input36 mV, 50 kohms
rec out (TAPE, VIDEO 1)200 mV, 470 ohms
pre out (subwoofer)1 V, 470 ohms
Tuner Section IconTuner Section
FM tuning range87.5-108.0 MHz
FM usable sensitivity (mono)11.2 dBf, 1.0 µV (75 ohms, IHF)
FM usable sensitivity (stereo)17.2 dBf, 2.0 µV (75 ohms, IHF)
FM signal-to-noise ratio (mono)76 dB, IHF
FM signal-to-noise ratio (stereo)70 dB, IHF
AM tuning range530-1, 710 kHz
AM usable sensitivity30 µV
AM signal-to-noise ratio40 dB
General IconGeneral
power supplyAC 120 V, 60 Hz
power consumption5.5 A
dimensions (W × H × D)17-1/8” × 5-7/8” × 14-13/16”
dimensions in mm (W × H × D)435 × 150 × 376 mm
weight21.4 lbs.
weight in kg9.7 kg